Product: Aussie Shield 300 PLM
Air Barrier Testing Results
Air Barrier Assembly
Material Air Permenance
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
0.012 L/(s·m²) @ 75 Pa
0.002 cfm/ft² @ 1.57 lb/ft²
0.0009 L/(s·m²)
0.002 cfm/ft² @ 1.57 lb/ft² @ nominal 20 mil (dry)
Water Vapor Transmittence Testing Results
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
778 ng / Pa•s•m2
1172 ng / Pa•s•m2
13.6 US Perms
20.5 US Perms