Product: Wall Guardian® FW-100-A Acrylic Based
Air Barrier Testing Results
Air Barrier Assembly
Material Air Permenance
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
< 0.0022 L/(s • m2) @ 75 Pa
0.0004 cfm /ft2 @ 1.57 psf
0.0005 L/(s • m2) @ 75 Pa
0.0001 cfm /ft2 @ 1.57 psf
@ 20 mils dry
@ 20 mils (dry)
Water Vapor Transmittence Testing Results
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
55.3 ng / Pa•s•m2
661 ng / Pa•s•m2
0.96 US Perms
11.5 US Perms
@ 22 mils (dry)
@ 22 mils (dry)
Product: Wall Guardian® FW-100 Asphaltic-component
Air Barrier Testing Results
Air Barrier Assembly
Material Air Permenance
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
< 0.0022 L/(s • m2) @ 75 Pa
< 0.00043 cfm /ft2 @ 1.57 psf
0.0069 L/(s • m2) @ 75 Pa
0.001358 cfm /ft2 @ 1.57 psf
@ 60 mils (wet) 35 mils (dry)
@ 30 mils (dry) 60 mils (wet)
Water Vapor Transmittence Testing Results
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
< 5.72 ng / Pa•s•m2
720 ng / Pa•s•m2
< 0.10 US Perms
12.6 US Perms
@ 30 mils (dry)
@ 30 mils (dry)