Evaluated Materials


Huntsman Building Solutions
Skip to your Product Type
Sprayed Polyurethane Foam (Medium Density Closed Cell)
Product: ProSeal (MD-C-200-v3)
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0106 L/(s • m2) @ 75 Pa
0.00212 cfm /ft2 @ 1.57 psf
0.00150 L/(s • m2) @ 75 Pa
0.00030 cfm /ft2 @ 1.57 psf
Material Thickness
@ 25mm (1.0")
@ 32 mm (1.29")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
68.9 ng / Pa•s•m2
74 ng / Pa•s•m2
Imperial
1.205 US Perms
1.3 US Perms
Material Thickness
@ 25mm (1.0")
@ 50mm (1.0")
Product: MD-C-200
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0803 L/(s • m2) @ 75 Pa
0.0161 cfm /ft2 @ 1.57 psf
0.0008 L/(s • m2) @ 75 Pa
0.00016 cfm /ft2 @ 1.57 psf
Material Thickness
@ 50mm (2.0")
@ 52mm (2.05")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
50.6 ng / Pa•s•m2
2748 ng / Pa•s•m2
Imperial
0.884 US Perms
48.09 US Perms
Material Thickness
@ 37mm (1.5")
@ 50mm (2.0")
Product: Heatlok® XT
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0383 L/(s • m2) @ 75 Pa
0.0076 cfm /ft2 @ 1.57 psf
0.020 L/(s • m2) @ 75 Pa
0.004 cfm /ft2 @ 1.57 psf
Material Thickness
@ 50mm (2.0")
@ 25mm
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
70.5 ng / Pa•s•m2
119 ng / Pa•s•m2
Imperial
1.23 US Perms
2.08 US Perms
Material Thickness
@ 25mm
@ 25mm
Product: Heatlok® Soy 200 Plus
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0022 L/(s • m2) @ 75 Pa
0.00044 cfm /ft2 @ 1.57 psf
0.004 L/(s • m2) @ 75 Pa
0.0008 cfm /ft2 @ 1.57 psf
Material Thickness
@ 100mm (4.0")
@ 25mm (1.0")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
Imperial
1.131 US Perms
Material Thickness
@ 25mm (1.0")
Product: Heatlok® HFO
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.001 L/(s • m2) @ 75 Pa
0.002 cfm /ft2 @ 1.57 psf
< 0.0001 L/(s • m2) @ 75 Pa
<0.0001 cfm /ft2 @ 1.57 psf
Material Thickness
@ 25mm (1.0")
@ 25mm (2.0")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
53.98 ng / Pa•s•m2
67.07 ng / Pa•s•m2
Imperial
0.94 US Perms
1.17 US Perms
Material Thickness
@ 25mm (1.0")
@ 25mm (1.0")
Product: Foam-Lok AB2000
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0915 L/(s • m2) @ 75 Pa
0.0183 cfm /ft2 @ 1.57 psf
0.000244 L/(s • m2) @ 75 Pa
0.000049 cfm /ft2 @ 1.57 psf
Material Thickness
@ 37mm (1.5")
@ 50mm (2.0")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
49 ng / Pa•s•m2
90 ng / Pa•s•m2
Imperial
0.8 US Perms
1.58 US Perms
Material Thickness
@ 50mm (1.97")
@ 50mm (2.0")
Self Adhered Sheet Membranes
Product: Heatlok ABS
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
0.89 ng / Pa•s•m2
1.8 ng / Pa•s•m2
Imperial
0.016 US Perms
0.031 US Perms