Product: Accufoam CC-HFO
Air Barrier Testing Results
Air Barrier Assembly
Material Air Permenance
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
0.0635 L/(s • m2) @ 75 Pa
0.0125 cfm /ft2 @ 1.57 psf
0.0016 L/(s • m2) @ 75 Pa
0.0003 cfm /ft2 @ 1.57 psf
Water Vapor Transmittence Testing Results
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
45.1 ng / Pa•s•m2
53.4 ng / Pa•s•m2
0.790 US Perms
0.935 US Perms
@ 50mm (2.0")
@ 50mm (2.0")