Evaluated Materials


SWD Urethane
Skip to your Product Type
Sprayed Polyurethane Foam (Medium Density Closed Cell)
Product: QUIK-SHIELD 112 XC
Air Barrier Testing Results
Property
Air Barrier Assembly
Material Air Permenance
Test Methods
Air Leakage Rate of Wall Assembly (ASTM E2357)
Air Leakage Rate of Material (ASTM E2178)
Results
0.0188 L/(s • m2) @ 75 Pa
0.00376 cfm /ft2 @ 1.57 psf
0.001 L/(s • m2) @ 75 Pa
0.0002 cfm /ft2 @ 1.57 psf
Material Thickness
@ 50 mm (2.0")
@ 26mm (1.0")
Water Vapor Transmittence Testing Results
Property
Water Vapor Permeance (ASTM E96 – desiccant method)
Water Vapor Permeance (ASTM E96 – water method)
Test Methods
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
Metric
65.62 ng / Pa•s•m2
145.86 ng / Pa•s•m2
Imperial
1.15 US Perms
2.550 US Perms
Material Thickness
@ 50mm (2.0")
@ 50mm (2.0")